TAKUMA
SITE TOP JAPANESE SITEMAP
Retrieval in Web Site
CORPORATE INFORMATION IR INFORMATION PRODUCTS GUIDE TECHNICAL INFORMATION CSR
TECHNICAL INFROMATION
New Technologies
Technical Review

SITETOP > Technical Information > New Technologies > Burnout Gas Re-circulating System

Burnout Gas Re-circulating System

Outline of the system

   The burnout gas is drawn from the furnace.  It is injected into the primary combustion gas after cooling at the heat exchanger.  This promotes mixing of the primary combustion gas. The oxygen in the burnout gas is used effectively for the combustion.   As a result, this system reduces the secondary air volume needed for a complete combustion.

(Click this picture to enlarge)

Operating data of demonstration test

This graphic chart shows the operating data of the demonstration in percentages compared with the regular operation (at the total excess-air ratio of 1.7~2.0).

(Click this picture to enlarge)

^ PAGE TOP